Controlled Impedance Cable - Tests

Contact Us

Tests Passed by Woven Controlled Impedance Cable

  • DWV 500VDC,<0.5 ma
  • Operating Voltage 5Vdc
  • IR>100Mohms
  • Transfer Impedance - Passed with Shielded CI Cable - details available
  • Shell-Ground Resistance - <75miliohms
  • Continuity - No Opens or Shorts, <4% Differential after Thermal Shock
  • Signal Integrity - Pass thru Signals at 38999 are Isolated
  • Grounding - Ground / Shield Wires are terminated to Pins, Connector Shell
  • Connectors - Mil-C-38999 Various, ARINC and UHD
  • Contacts - Fully Populated Connectors
  • Conductors, Wire - per NEMA MW-28C, Woven CI Cable
  • Outer Covering - Zippertubing ZT-T if needed
  • Markers - Wrap Around Type
  • Dissimilar Metals - per MIL-STD 889
  • Prohibited Materials - per MIL-DTL-81381
  • Encapsulation - per MIL-M-24041 (Usually Urethane) 
  • Captive Hardware - Required Hardware per SCD
  • Protective Caps - as Required
  • PWB - per IPC-2221 C3 per IPC6012 C3 (for termination)
  • Conformal Coat - per Mil-I-45058, TAR
  • Min Ben Radius -.13
  • Soldering - J-STD-001
  • Durability - 100 matings for UHD
  • Cable Retention - 15lbs at 38999, 10lbs at UHD
  • Mating Force - per MIL-DTL-38999
  • Workmanship - IPC-A-620 C3
  • Temperature Rating - 
  • Operating -54C-+71C
  • Storage -54C-+95C