Tests Passed by Woven Controlled Impedance Cable
- DWV 500VDC,<0.5 ma
- Operating Voltage 5Vdc
- IR>100Mohms
- Transfer Impedance - Passed with Shielded CI Cable - details available
- Shell-Ground Resistance - <75miliohms
- Continuity - No Opens or Shorts, <4% Differential after Thermal Shock
- Signal Integrity - Pass thru Signals at 38999 are Isolated
- Grounding - Ground / Shield Wires are terminated to Pins, Connector Shell
- Connectors - Mil-C-38999 Various, ARINC and UHD
- Contacts - Fully Populated Connectors
- Conductors, Wire - per NEMA MW-28C, Woven CI Cable
- Outer Covering - Zippertubing ZT-T if needed
- Markers - Wrap Around Type
- Dissimilar Metals - per MIL-STD 889
- Prohibited Materials - per MIL-DTL-81381
- Encapsulation - per MIL-M-24041 (Usually Urethane)
- Captive Hardware - Required Hardware per SCD
- Protective Caps - as Required
- PWB - per IPC-2221 C3 per IPC6012 C3 (for termination)
- Conformal Coat - per Mil-I-45058, TAR
- Min Ben Radius -.13
- Soldering - J-STD-001
- Durability - 100 matings for UHD
- Cable Retention - 15lbs at 38999, 10lbs at UHD
- Mating Force - per MIL-DTL-38999
- Workmanship - IPC-A-620 C3
- Temperature Rating -
- Operating -54C-+71C
- Storage -54C-+95C